Application Information
|
Tenant Relocation Assistance
Residential Unit Occupancy:
Some/All Units Occupied by Residential Tenant
GROUND DISTURBANCE
Land Disturbing Activity:
Yes
PERMIT APPLICATION COMMON
Is work in the right-of-way (street or alley) required?:
No
Choose the Primary Property Use:
Commercial
Project Value:
83000000
PERMIT TRACKING COMMON
Review Level:
Full C
Application Completed Date:
07/17/2018
Decision Date:
01/02/2020
Permit Remarks:
Application deemed complete June 28, 2018. Sign inspection request date.
|
Other Information
|
LAND USE PROPOSED |
Use: Multifamily Residential Use Sq. Ft.: 0 Floor(s): n/a |
Use: Restaurant Sq. Ft.: 0 Floor(s): n/a |
Use: General Retail Sales & Service Sq. Ft.: 0 Floor(s): n/a |
Use: Multifamily Residential Use Sq. Ft.: 0 Floor(s): n/a |
|
HOUSING UNITS |
Type of Housing Unit: Apartment Number of Existing Units: 0 Number of Removed Units: 0 Number of Added Units: 2 Number of Sleeping Rooms: 0 |
|
LAND USE NOTICES |
Notice Type: Application Status: Notice Published Is Renotice?: No Sign Type: Environmental/Large Sign 300 ft Mailer?: No Comments: See attachments link above for complete notice and supporting documents.
extension requested by C. Newman Publication Date: 08/06/2018 End of Comment Period: 08/20/2018 End of Extended Comment Period: 09/03/2018 Notice Record Number: 001160-18PN |
Notice Type: SDCI Director's Analysis and Decision Status: Notice Published Is Renotice?: No Sign Type: None Publication Date: 01/02/2020 End of Appeal Period: 01/16/2020 Notice Record Number: 002244-19PN |
Notice Type: Design Review Board Recommendation Meeting Status: Notice Published Is Renotice?: No Sign Type: Placards 300 ft Mailer?: No Comments: REC Meeting
Notice on 1/24/18 Publication Date: 01/24/2019 End of Comment Period: 02/11/2019 Date of Meeting/Hearing: 02/12/2019 Time of Meeting/Hearing: 5:30 PM Location of Meeting/Hearing: Seattle City Hall, 600 4th Ave, Room L280 Notice Record Number: 000213-19PN |
Notice Type: Appeal Hearing Status: Notice Published Is Renotice?: No Sign Type: None Comments: MUP -20-003 (Save the Market Entrance, MUP-20-004 (The Newmark Building Owner's Assn) Publication Date: 03/16/2020 Date of Meeting/Hearing: 04/06/2020 Time of Meeting/Hearing: NaN:00 AM Location of Meeting/Hearing: Office of Hearing Examiner, Hearing Room, Room 4000, 700 5th Avenue, SMT 40th Floor Notice Record Number: 000542-20PN |
Notice Type: Change in Appeal Hearing Schedule Status: Notice Published Is Renotice?: No Sign Type: None Comments: MUP-20-003; MUP-20-004 ORDER ON STAY OF PROCEEDINGS - PREHEARING CONFERENCE 6/1/2020 9:00 AM OFFICE OF THE HEARING EXAMINER, STE 4000, 700 5TH AVE (SMT 40TH FL) Publication Date: 04/09/2020 Date of Meeting/Hearing: 06/01/2020 Time of Meeting/Hearing: NaN:00 AM Location of Meeting/Hearing: HEARING EXAMINER, STE 4000, 700 5TH AVE (SMT 40TH FL) Notice Record Number: 000681-20PN |
|
LAND USE CONDITIONS |
Record Type: MUP Condition Category: Prior to Permit Issuance Condition Details: 1. The applicant shall document on the MUP drawings, the location of a future art installation on the building’s south-facing façade as documented in the Recommendation design packet. Verification Group: LU Reviewer |
Record Type: Construction Condition Category: Prior to Permit Issuance Condition Details: 2. The applicant shall note on the final architectural drawings that the final design of the gas meter screening is subject to approval by the SDCI Land Use Planner. Verification Group: LU Reviewer |
Record Type: Construction Condition Category: Prior to Permit Issuance Condition Details: 3. The applicant shall submit written documentation from a technical expert (mechanical consultant, architect, etc.) if horizontal coverage of any exposed rooftop mechanical area is infeasible. This documentation shall be considered prior to approval of the final design of the horizontal screening to the mechanical equipment by the assigned SDCI Land Use Planner in coordination with pertinent SDCI reviewers (Zoning, Ordinance, Mechanical). Verification Group: LU Reviewer |
Record Type: Construction Condition Category: Prior to Permit Issuance Condition Details: 4. In addition to the location of the future art installation on the building’s south-facing façade, the applicant shall note on the final architectural plans information regarding future art installation timing parameters and a statement that the final design of this art installation will be subject to approval by the assigned SDCI Land Use Planner. Verification Group: LU Reviewer |
Record Type: MUP Condition Category: Prior to Final Inspection Condition Details: 5. The Land Use Planner shall inspect art installations, lighting, signage, materials, colors, and design of the constructed project. All items shall be constructed and finished as shown at the design Recommendation meeting and the subsequently updated Master Use Plan set. Any change to the proposed design, materials, or colors shall require prior approval by the Land Use Planner (Tami Garrett, tami.garrett@seattle.gov) or a SDCI assigned Land Use Planner. Verification Group: LU Reviewer |
Record Type: MUP Condition Category: For Life Condition Details: 6. The building and landscape design shall be substantially consistent with the materials represented at the Recommendation meeting and in the materials submitted after the Recommendation meeting, before the MUP issuance. Any change to the proposed design, including materials or colors, shall require prior approval by the Land Use Planner (Tami Garrett, tami.garrett@seattle.gov) or a SDCI assigned Land Use Planner. Verification Group: Complaint |
Record Type: Construction Condition Category: Prior to Permit Issuance Condition Details: 7. Provide a Construction Management Plan that has been approved by Seattle Department of Transportation (SDOT). The submittal information and review process for Construction Management Plans are described on the SDOT website at: Construction Use in the Right of Way Verification Group: LU Reviewer |
Record Type: Construction Condition Category: Prior to Permit Issuance Condition Details: 8. If the applicant intends to work outside of the limits of the hours of construction described in condition #10, a Construction Noise Management Plan shall be required, subject to review and approval by SDCI Noise Abatement staff, and prior to a demolition, grading, or building permit, whichever is issued first. The construction noise management plan may be modified as needed through SDOT and SDCI review. The construction noise management plan shall be incorporated into the Construction Management Plan. Verification Group: LU Reviewer |
Record Type: Construction Condition Category: Prior to Permit Issuance Condition Details: 9. A Loading Dock Management Plan shall be prepared to manage deliveries at the alley and shall be reviewed and is subject to approval by the SDCI Transportation Planner and the Seattle Department of Transportation (SDOT). The objective of the dock management plan shall be to manage deliveries so that vehicles are not waiting in the alley to access the loading berth. The plan shall include but not be limited to the following items:
• The management plan shall coordinate deliveries between the hotel and other tenants and their vendors.
• Vendors shall be provided performance specifications, including the Loading Dock Management Plan and the 30-minute limit on parking and loading in the alley.
• A loading dock manager shall be responsible for administering and managing compliance of vendors with the performance specifications.
• The hours of operation of the loading dock shall be limited to hours outside of noon to 6:00 PM.
• The hours of operation shall be posted near the loading dock door.
• Trucks shall be directed to enter the alley from Pike Street and exit from Union Street.
• Site tenants shall notify suppliers and other making deliveries of the maximum truck size that can be accommodated within the loading bay.
• Signs shall be posted near the loading dock door on the size of vehicles accommodated within the loading bay.
• Vehicles using the loading dock shall be accommodated fully within the loading bay.
• Delivery trucks shall not be allowed to idle in the alley; signs shall be posted alerting drivers to this restriction.
Verification Group: LU Reviewer |
Record Type: Construction Condition Category: During Construction Condition Details: 10. Construction activities (including but not limited to demolition, grading, deliveries, framing, roofing, and painting) shall be limited to non-holiday weekdays from 7:00 AM to 6:00 PM. Interior work that involves mechanical equipment, including compressors and generators, may be allowed on Saturdays between 9:00 AM and 6:00 PM once the shell of the structure is completely enclosed, provided windows and doors remain closed. Non-noisy activities, such as site security, monitoring, weather protection shall not be limited by this condition. This condition may be modified through a Construction Noise Management Plan, required prior to issuance of a building permit as noted in condition #8. Verification Group: Complaint |
|
LAND USE HEARING |
Hearing Type: Appeal Hearing Body: Hearing Examiner Appealed By: Appellants - Save the Market Entrance & The Newmark Building Owner's Assn Hearing Decision: MUP -20-003 (Save the Market Entrance, MUP-20-004 (The Newmark Building Owner's Assn) |
|
HANSEN_BILLING_CREDIT |
Fee Group: Everything else on Land Use Min Fee Covers: 10 Remaining Hours: 0 |
Fee Group: Pre-Sub Conference Min Fee Covers: 2 Remaining Hours: 0 |
|
Parcel Information
|
Development Site Parcel:DV0010023 Legal Description:LOT 1, BLK 25, A.A. DENNY'S THIRD, EXC NW 3.5' COND FOR PIKE ST UNDER CO 11417 & EXC SW 9' COND FOR 1ST AV UNDER CO 1129
|
|